EXdip 910 is an immersion fitting made of stainless steel with flanged connection and integrated orbital sensor cleaning system for nominal diameter DN50 / 2”. The probe housing is firmly screwed by a flange connection.The built-in sensor is accommodated securely in a protective cage. Directly in the range of the sensor the highly effective orbital cleaning flushing ensures a mechanical cleaning of the sensor. The immersion fitting is available in various lengths.

EXdip 910

Your advantages

  • Robust design
  • Integrated orbital sensor cleaning system
  • Extension of sensor-lifetime and reduction of maintenance efforts
  • Easy installation and removal of the sensor holder
  • Stainless steel AISI 316L / 1.4404
  • Immersion length 500-2500mm
  • Minimum size DN50 / 2”
  • Up to 10 bar and 140 °C
  • No external cleaning devices necessary

Configuration

  • Specifications

    Max. pressure 10 bar
    Max. temperature 140°C
    Material 1.4404 / AISI 316L
    Sealing material EPDM or FPM (Viton)
    Immersion lengths 0.5 up to 2.5meters
    Flange sizes DIN DN50 / ANSI 2"
    Sensor cleaning integrated orbital spray cleaning (option)
    Certificates material
  • Dimensions

    EXdip 910
    EXdip 910
  • Applications

    • For all kind of Ø12/120mm sensors with thread PG13.5 (pHglass- and ISFET sensors, conductivity- or temperature sensors, turbidity and other optical sensors)
    • Chemicals
    • Water and wastewater
    • Permanent installation in tanks, vessels or open channels
  • Downloads

Your direct inquiry




We are looking forward to hearing from you:

Exner Process Equipment GmbH
Carl-Metz-Straße 26

76275 Ettlingen
Deutschland

Telefon: +49 (0)7243-94 54 29-0
Fax: +49 (0)7243-94 54 29-99

E-Mail: sales@e-p-e.de

Related products


This website uses cookies. By continuing to use the website, you agree to the use of cookies. Further information can be found in our Data Protection Statement.